CLINICAL ORAL INVESTIGATIONS, cilt.13, sa.1, ss.29-35, 2009 (SCI-Expanded)
The purpose of this study was to determine colour changes in a composite cured with tungsten-halogen, light-emitting diode (LED) or a plasma arc after 5 years. Five specimens 10 mm in diameter and 2 mm in height were prepared using Hybrid (Clearfil AP-X) composite for each test group. The corresponding specimens were cured with a tungsten-halogen curing light, a LED unit or with a plasma arc. Specimens were stored in light-proof boxes for 5 years after the curing procedure to avoid further exposure to light and stored in 37A degrees C in 100% humidity. Colorimetric values of the specimens immediately after curing and after 5 years were measured using colorimeter. The Delta E* (ab) values varied significantly depending on the curing unit used (p < 0.001). Curing time did not affect the colour changes of the specimens (p = 0.4). The results of this study suggest that composite materials undergo measurable changes due to the curing unit exposure.