DETERMINATION OF PARAMETERS FOR DOUBLE-SIDE LINEAR PERMANENT MAGNETS SYNCHRONOUS MOTOR


Creative Commons License

Otkun O., Akpinar A. S.

PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, vol.21, no.2, pp.52-58, 2015 (ESCI) identifier

Abstract

In this study, the test results were compared with the parameters specified and determination of parameters of the design Double-Side Linear Permanent Magnet Synchronous Motor. Firstly given the design details of the motor and then transferred to the methods used to obtain the parameters of the motor. Three different methods were used in finding the parameters. The first of these methods, the classical method, the experimental method. The second is a digital LCR meter sensitive results obtained. The third one the motor drive LG-SV022IG5A-4 results obtained from the product code. With these results, the motor was tested with the help of computer software is prepared. From the results of the test current, frequency, and the results were evaluated given pushing force and speed graphics.