The biomechanical comparison of screw fixation and cross pinning methods in salter harris type 2 distal femoral fractures using the finite element method


ÖNER K., ÖZER A., PAKSOY A. E.

ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, cilt.12, sa.2, ss.205-209, 2021 (ESCI) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 12 Sayı: 2
  • Basım Tarihi: 2021
  • Doi Numarası: 10.4328/acam.20415
  • Dergi Adı: ANNALS OF CLINICAL AND ANALYTICAL MEDICINE
  • Derginin Tarandığı İndeksler: Emerging Sources Citation Index (ESCI)
  • Sayfa Sayıları: ss.205-209
  • Anahtar Kelimeler: Finite element, Cross pinning, Screw fixation, Physis fracture, PHYSEAL FRACTURES, EPIPHYSEAL PLATE, GROWTH-PLATE, INJURIES, CHILDREN
  • Karadeniz Teknik Üniversitesi Adresli: Evet

Özet

Aim: The most common type of distal femur physis fractures is Salter-Harris type 2 (SH type 2). These fractures have high complication rates and can cause a significant loss of function. Anatomical reduction is important in treatment. In this study, we aimed to compare two methods commonly used in SH type 2 fractures, cross pinning, and two parallel screw fixation methods using the finite element method.