Pushover and nonlinear time history analysis evaluation of a RC building collapsed during the Van (Turkey) earthquake on October 23, 2011


Cavdar O., Bayraktar A.

NATURAL HAZARDS, vol.70, no.1, pp.657-673, 2014 (SCI-Expanded) identifier identifier

  • Publication Type: Article / Article
  • Volume: 70 Issue: 1
  • Publication Date: 2014
  • Doi Number: 10.1007/s11069-013-0835-3
  • Journal Name: NATURAL HAZARDS
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.657-673
  • Karadeniz Technical University Affiliated: Yes

Abstract

The nonlinear seismic behavior of a collapsed reinforced concrete (RC) residential building in the city of Van in Turkey is investigated by the static pushover and nonlinear time history analyses. The selected RC structure was designed according to the 1975 version of Turkish Earthquake Code (TEC-1975). The building had experienced heavy damage, and it was demolished in the Van earthquake on October 23, 2011. The 2007 version of Turkish Earthquake Code (TEC-2007) is considered for the assessing seismic performance evaluation of the selected RC building. The RC structure presents collapse performance level under the earthquake loads. Besides, the analytical solutions show that different performance levels for the sections are obtained from the pushover and nonlinear time history methods.